HomeGuidesAPI ReferenceChangelog
Terms of Use
Guides
Terms of Use

Setup Smart Charging (Public, Private, Personal/Home)

Configure the Smart Charging settings

disabled - no smart charging is available for the charge point
tod - for public and private charge points. The maximum load for a specific time period during the day could be set - the charge point could be part of a dynamic load management circuit.
dynamic - for public and private charge points. The charge point could be part of a dynamic load management circuit.
user_schedule - for personal charge points. The maximum power load will be defined on the EVSE level. The charge point owner could manually create a charging schedule.

Define the type and parameters of Smart Charging using a user schedule, Dynamic Load Management Circuit (see ENERGY MANAGEMENT) or Time of Day

curl --location 'https://{{baseUrl}}/public-api/resources/charge-points/v2.0/10/smart-charging' \ --header 'Content-Type: application/json' \ --header 'Accept: application/json' \ --header 'Authorization: Bearer {{apiToken}}' \ --data '{ "defaultChargePointMaxCurrent": 48, "mode": "tod", "periods": [ { "weekDay": "wed", "elements": [ { "startAt": "08:00", "endAt": "09:00", "maxCurrent": 24 }, { "startAt": "22:00", "endAt": "23:00", "maxCurrent": 48 } ] }, { "weekDay": "thu", "elements": [ { "startAt": "08:00", "endAt": "09:00", "maxCurrent": 24 }, { "startAt": "22:00", "endAt": "23:00", "maxCurrent": 48 } ] } ], "minCurrent": 12, "enableKeepAwake": true, "maxVoltage": "400", "phases": "three_phase", "phaseRotation": "TSR" }'

RESPONSE Status: 201 Created

{ "data": { "mode": "tod", "defaultChargePointMaxCurrent": 48, "periods": [ { "weekDay": "wed", "elements": [ { "startAt": "08:00", "endAt": "09:00", "maxCurrent": 24 }, { "startAt": "22:00", "endAt": "23:00", "maxCurrent": 48 } ] }, { "weekDay": "thu", "elements": [ { "startAt": "08:00", "endAt": "09:00", "maxCurrent": 24 }, { "startAt": "22:00", "endAt": "23:00", "maxCurrent": 48 } ] } ], "minCurrent": 6, "enableKeepAwake": false, "maxVoltage": "400", "phases": "three_phase", "phaseRotation": "TSR" } }